Insulation Calculator
Find how much insulation you need for an attic floor, walls, or floors. In the UK, insulation on the attic floor is called loft insulation. For roof insulation between the rafters, measure the sloped area. Enter the area, your target R-value, and the R-value of any insulation already there to see the R-value to add, how many bags of blown-in insulation to buy, or how many packages of batts or rolls.
Add more areas, or subtract areas you won't insulate, such as doors and windows in a wall.
- Choose US or Metric. This also sets the R-value unit to R or RSI and the bag charts in the results. You can still change the unit of any single field.
- Enter the area to insulate. For an attic floor, enter its Length and Width. For the walls of a room, choose Room walls and enter the wall Height too. Use Add section for more areas, and set a section to Subtract for doors and windows in a wall.
- Choose the Insulation type: Blown-in for loose-fill on an open attic floor, or Batts or rolls for attics, walls, and floors.
- Enter your Target R-value and, if there is insulation already, its Existing R-value. For batts or rolls, the target is optional.
- Check the Waste allowance. It starts at 10%.
- For blown-in, the results list the bags for each chart. To use the chart on your own bag, enter its coverage per bag as a Custom bag coverage. For batts or rolls, enter the Coverage per package printed on the package to see how many to buy.
- Optionally, enter a price per bag, per package, or per area to estimate the cost. For an installer's quote by area, choose a price per ft² or m².
Dimension fields accept whole numbers, decimals, fractions, and mixed
numbers, such as 12, 10.5, 3/4, or
8 1/2. Enter R-values as numbers only, such as
30 for R-30 or 5.28 for RSI 5.28.
How much insulation you need
The calculator adds up the area to insulate and adds the waste allowance:
Total area = net area × (1 + waste % ÷ 100)
Layers of insulation add up, so the R-value you need to add is what's left after the insulation already there:
R-value to add = target R-value − existing R-value
For blown-in insulation, the calculator finds the row of the bag's coverage chart for the R-value to add, and divides by the coverage of one bag on that row. For batts or rolls, it divides by the area printed on the package:
Bags = total area ÷ coverage per bag, rounded up
Packages = total area ÷ coverage per package, rounded up
When the R-value to add falls between two rows of a chart, the calculator uses the higher row. The label R-value is only promised at the coverage and depth on a row, so it doesn't average between rows. Rounding up gives a few more bags, not too few. Below the lowest row, it uses the lowest row. Above the highest row, the chart doesn't say how far a bag goes, so that bag is left out of the results.
Measure an attic floor's length and width, and walls and floors with the studs or joists included. For a sloped ceiling, measure along the slope. The area of each shape is calculated as follows:
| Shape | Area |
|---|---|
| Rectangle | length × width |
| Circle | π × diameter² ÷ 4 (or π × radius²) |
| Triangle (base and height) | base × height ÷ 2 |
| Triangle (three sides) | Heron's formula: √(s(s − a)(s − b)(s − c)), where s = (a + b + c) ÷ 2 |
| Trapezoid | (parallel side A + parallel side B) ÷ 2 × height |
| Ring | π × (outer diameter² − inner diameter²) ÷ 4 |
| Rectangular border | outer length × outer width − (outer length − 2 × border width) × (outer width − 2 × border width) |
| Known area | the area you enter |
| Room walls | 2 × (length + width) × height |
Blown-in insulation coverage charts
Every bag of blown-in insulation sold in the US has a coverage chart on its label, with the most area one bag may cover and the minimum depth for each R-value. In the tables below, these are the Coverage and Depth columns. The calculator uses these charts from the makers' product data. The coverage is the net coverage, with no adjustment for framing, and the depth is the minimum depth right after blowing, which you can check with a ruler standing in the attic. When you add to existing insulation, the depth is for the new layer.
Fiberglass, 27.5 lb bags (Owens Corning AttiCat chart)
| R-value | Coverage | Depth |
|---|---|---|
| R-13 | 169.8 ft² | 5 in |
| R-19 | 110.7 ft² | 7 in |
| R-22 | 94.8 ft² | 8 in |
| R-26 | 79.3 ft² | 9.5 in |
| R-30 | 68.5 ft² | 10.75 in |
| R-38 | 52.6 ft² | 13.5 in |
| R-44 | 44.6 ft² | 15.5 in |
| R-49 | 39.9 ft² | 17 in |
| R-60 | 31.8 ft² | 20.5 in |
Source: Owens Corning, AttiCat PINK Blown-In Insulation Product Data Sheet (Pub. No. 10011273-L, May 2026).
Cellulose, 25 lb bags (Greenfiber Sanctuary chart)
| R-value | Coverage | Depth |
|---|---|---|
| R-13 | 65.8 ft² | 3.9 in |
| R-19 | 44.2 ft² | 5.7 in |
| R-22 | 38.0 ft² | 6.6 in |
| R-30 | 25.9 ft² | 8.9 in |
| R-38 | 19.0 ft² | 11.2 in |
| R-44 | 15.7 ft² | 12.9 in |
| R-49 | 14.1 ft² | 14.3 in |
| R-60 | 11.6 ft² | 17.3 in |
Source: Greenfiber, SANCTUARY Attic Card (PM-6.3330-SDBZ Rev A 04/26), net coverage.
Fiberglass, 30 lb bags (Owens Corning AttiCat (Canada) chart)
| R-value | Coverage | Depth |
|---|---|---|
| RSI 2.1 | 15.05 m² | 114 mm |
| RSI 2.8 | 11.29 m² | 151 mm |
| RSI 3.5 | 9.03 m² | 189 mm |
| RSI 4.2 | 7.53 m² | 227 mm |
| RSI 4.9 | 6.45 m² | 265 mm |
| RSI 5.6 | 5.63 m² | 302 mm |
| RSI 6.3 | 4.94 m² | 337 mm |
| RSI 7.0 | 4.40 m² | 372 mm |
| RSI 7.7 | 3.96 m² | 407 mm |
| RSI 8.4 | 3.60 m² | 442 mm |
| RSI 8.75 | 3.46 m² | 458 mm |
| RSI 9.1 | 3.30 m² | 477 mm |
| RSI 9.8 | 3.05 m² | 511 mm |
| RSI 10.5 | 2.83 m² | 546 mm |
| RSI 11.2 | 2.64 m² | 581 mm |
| RSI 11.9 | 2.48 m² | 615 mm |
| RSI 12.25 | 2.41 m² | 632 mm |
| RSI 12.6 | 2.33 m² | 650 mm |
| RSI 13.3 | 2.21 m² | 684 mm |
| RSI 14.1 | 2.07 m² | 724 mm |
Source: Owens Corning Canada, AttiCat Expanding Blown-In Insulation Product Data Sheet (Pub. No. 501140D, June 2025).
Makers revise these charts. For example, Owens Corning's 2010 AttiCat chart was for a 28.5 lb bag that covered 38.8 ft² at R-49, and recent charts are for a 27.5 lb bag that covers 39.9 ft². Check the chart on your bag, and if it differs, enter its coverage for the R-value you need to add as a custom bag coverage. Do the same for blown-in bags in the UK, Australia, and elsewhere.
These charts are for blowing onto an open attic floor. Blowing into closed walls (dense packing) needs a different chart and machine, and Owens Corning says the AttiCat machine isn't meant for walls.
R-value, RSI, and existing insulation
R-value measures how well insulation resists heat flow. In the US it's written as R-30, in ft²·°F·h/Btu. In metric units it's called RSI, in m²·K/W. R-1 is about RSI 0.176, and RSI 1 is about R-5.68. In Australia and New Zealand, R-values such as R4.0 are already in metric units, so R4.0 there is RSI 4.0.
For existing insulation, use the R-value on its label. Without a label, you can estimate it from the depth. The US Department of Energy's Insulation Fact Sheet suggests multiplying the thickness in inches by 3.2 for fiberglass batts under a floor, and Greenfiber's attic instructions say about 6 in of fiberglass batts is R-19.
New insulation on top can squash the old layer a little. The same DOE fact sheet suggests adding about 1 extra inch over old fiberglass, or about ½ in over rock wool or cellulose. The calculator doesn't include this, so add it to the depth if you want to allow for it.
What R-value to aim for
The right R-value depends on your climate, the part of the house, and local rules, so the calculator doesn't assume one. These are examples, not code requirements:
- In the US, ENERGY STAR's Recommended Home Insulation R-Values list, for an attic with no insulation, R30 in climate zone 1, R49 in zones 2 and 3, and R60 in zones 4 to 8, and R13 to R38 for floors. The table is based on the 2021 International Energy Conservation Code. Look up your zone on the ENERGY STAR page.
- In walls, the depth of the studs sets the R-value that fits. Owens Corning's batts are 3.5 in thick at R-13 and R-15 for 2 × 4 walls, and 5.5 in at R-21. Squeezing a thicker batt into a thinner wall lowers its R-value, such as an R-19 batt made for 6¼ in in a 5½ in wall.
- In the UK, loft insulation is usually given as a depth, and Wickes recommends at least 270 mm. Choose Batts or rolls, leave the target R-value blank, and enter the area of the rolls for each layer.
- In Australia, Knauf Insulation recommends R4.0 ceiling batts in Queensland and R6.0 in New South Wales, Victoria, and other states for a ceiling with no insulation.
Extra insulation for waste
The waste allowance starts at 10% for both types. For blown-in insulation, Greenfiber says job conditions, technique, and machine settings can change the actual coverage by as much as 10%, and the chart coverage is the most a bag may cover. For batts or rolls, it covers cutting them to length and around obstacles, the same as for drywall and flooring.
The area includes the studs or joists, where no insulation goes, so the count is a little high. In walls, a few percent extra remains even with the waste allowance at 0%.
Examples
Topping up an attic
An attic floor 40 ft × 25 ft is 1,000 ft², or 1,100 ft² with 10% added. To go from R-19 to R-49, you add R-30. On the R-30 row, that is 1,100 ÷ 68.5 = 16.06, so 17 bags of 27.5 lb fiberglass at least 10.75 in deep, or 1,100 ÷ 25.9 = 42.47, so 43 bags of 25 lb cellulose at least 8.9 in deep. At $35.00 per fiberglass bag, the cost is $595.00.
Batts for the walls of a room
The walls of a room 30 ft × 20 ft with 8 ft walls are 800 ft². Subtracting six windows of 3 × 4 ft and two doors of 3 × 7 ft leaves 686 ft², or 754.6 ft² with 10% added. With R-13 batts in packages of 106.6 ft², that is 754.6 ÷ 106.6 = 7.08, so 8 packages.
Metric dimensions
An attic floor 10 m × 8 m is 80 m², or 88 m² with 10% added. To go from RSI 2.1 to RSI 8.8, you add RSI 6.7 (R-38.04), which falls between the RSI 6.3 and 7.0 rows of the Canadian AttiCat chart. On the RSI 7.0 row, 88 ÷ 4.40 = 20, so 20 bags of 30 lb at least 372 mm deep.
FAQ
About 17 to 35 bags of 27.5 lb fiberglass, or 43 to 95 bags of 25 lb cellulose, for R-30 to R-60. With 10% extra, 1,000 ft² becomes 1,100 ft². With no insulation there now, the bags for each target are:
| Target | Fiberglass | Cellulose |
|---|---|---|
| R-30 | 17 bags | 43 bags |
| R-38 | 21 bags | 58 bags |
| R-49 | 28 bags | 79 bags |
| R-60 | 35 bags | 95 bags |
These use the charts for 27.5 lb bags of Owens Corning AttiCat fiberglass and 25 lb bags of Greenfiber Sanctuary cellulose. Other bags differ, so check the chart on yours.
Yes. ENERGY STAR says you can add loose fill on top of fiberglass batts or blankets, and the other way around. Enter the R-value already there as the existing R-value, and the calculator works out the R-value to add.
Multiply by about 0.176. For example, R-30 is about RSI 5.28, and R-49 is about RSI 8.63. To go from RSI to R, multiply by about 5.68.
Related calculators
- Square Footage Calculator
Area in square feet, square yards, and square meters.
- Drywall Calculator
How many sheets of drywall to buy for walls and ceilings, by sheet size.
- Framing Calculator
How many studs and plates to buy for wood-framed walls, with corners, openings, and the cost.
- Heat Loss Calculator
Heat loss in BTU/h and watts through walls, windows, doors, ceilings, and floors, plus air leakage.
- Flooring Calculator
Flooring area including waste for your layout, and how many boxes to buy.
- Carpet Calculator
How much carpet to buy from a roll for a room, with the seams, and the cost with pad and installation.